Your Trusted Source For Livestock Farming Equipment

Livestock Cooling Pad for Barn Evaporative Cooling Systems

This livestock cooling pad is an evaporative wet wall cooling media used in cattle barns, pig houses, poultry houses, greenhouses and agricultural ventilation buildings. When paired with negative pressure fans or exhaust fans, the cooling pad helps bring outside air through the wet honeycomb surface, supporting faster temperature reduction, better airflow and more stable cooling performance in hot farm environments.


Product Overview

This livestock cooling pad is a wet wall evaporative cooling media for barns, greenhouses and agricultural ventilation buildings. The pad uses a honeycomb corrugated structure to increase the contact area between water and incoming air. When warm outside air passes through the wet pad surface, evaporation helps lower air temperature before the air enters the building.

For livestock barns, cooling pads are commonly used together with negative pressure fans or exhaust fans. The fan pulls air through the wet pad wall, creating a more effective cooling and ventilation path across the barn. This fan-and-pad cooling system is suitable for hot seasons, high-density housing and farm buildings that need better air exchange.

The product supports customized height and width, multiple thickness options, frame materials, density types, colors and water inlet/outlet methods. It can be configured for cattle barns, pig houses, poultry houses, greenhouses, workshops and other farm ventilation projects.

Livestock cooling pad features with fast evaporative cooling custom size frame options and density options

Product Features

  • Fast Evaporative Cooling: The wet honeycomb surface helps cool incoming air through water evaporation.
  • Works with Negative Pressure Fans: Cooling performance is stronger when the pad is paired with exhaust fans or negative pressure fans.
  • Thickened Pad Options: Thickness options include 10 cm, 15 cm and 20 cm for different cooling and installation needs.
  • Custom Height and Width: The pad wall can be customized according to the building opening and ventilation layout.
  • Honeycomb Corrugated Media: The corrugated structure supports water distribution, air passage and evaporative contact area.
  • Virgin Pulp Paper Direction: The pad media can be made with virgin pulp paper or high-density cellulose cooling material for stronger structure and longer use.
  • Multiple Frame Materials: Galvanized sheet frame, aluminum alloy frame and stainless steel frame options can be selected by project environment.
  • Multiple Water Inlet and Outlet Methods: Side inlet, top inlet, bottom outlet and side outlet combinations can be configured according to installation needs.
  • Multiple Density Options: 7090, 6090 and 5090 pad types can be selected according to airflow, cooling and density requirements.
  • Multiple Color Options: Brown, green, black, brown-green mixed and surface color options can be supplied by production batch and project requirement.

Configuration Options

ConfigurationBest ForMain AdvantageBuyer Notes
10 cm Cooling PadSmaller buildings or limited installation spaceThinner structure and easier installationConfirm cooling demand and fan size
15 cm Cooling PadCommon livestock barns and greenhousesBalanced cooling and airflow performanceSuitable for many farm projects
20 cm Cooling PadHigher cooling demand or thicker wall designLarger pad thickness for stronger cooling media volumeConfirm frame and opening size
Galvanized Sheet FrameGeneral farm projectsPractical frame option for many installationsConfirm corrosion conditions
Aluminum Alloy FrameProjects needing lighter frame and cleaner appearanceGood appearance and stable frame structureConfirm budget and environment
Stainless Steel FrameHumid, corrosive or higher-standard projectsBetter corrosion resistanceConfirm project requirement
7090 Pad TypeStandard barn cooling useCommon evaporative cooling pad typeConfirm airflow and fan matching
6090 Pad TypeMedium density requirementAlternative airflow and cooling balanceConfirm project design
5090 Pad TypeHigher density requirementHigher density pad optionConfirm pressure drop and fan matching
Custom Cooling Pad WallBarns, greenhouses and workshop projectsHeight, width, thickness, frame and water flow can be matchedProvide opening size and layout drawing

Product Comparison

FeatureLivestock Cooling PadNegative Pressure FanAir Conditioner
Main FunctionEvaporative cooling and humidified air intakeAir exhaust and airflow controlMechanical cooling
Best UseBarn wet wall cooling systemsBarn ventilation and air exchangeOffices or controlled indoor spaces
System RoleCools incoming air before it enters the buildingPulls air through the building and pad wallCools enclosed indoor air
Energy UseMainly water circulation and fan system supportFan power consumptionHigher energy consumption
Best PairingNegative pressure fan or exhaust fanCooling pad wallInsulated closed room
Farm SuitabilitySuitable for livestock barns, greenhouses and agricultural buildingsSuitable for livestock barns and workshopsUsually not practical for large open barns
CustomizationPad size, thickness, frame, density and water flow directionFan size, power and airflowUnit capacity and room size
Recommended BuyerFarms needing wet wall coolingFarms needing ventilation and air movementNon-livestock indoor cooling projects

Technical Specifications

Livestock cooling pad specifications with 10 15 20 cm thickness frame options water inlet options and density types
ItemAvailable / Reference Specification
Product TypeLivestock cooling pad / evaporative cooling pad wall
Main UseBarn cooling, evaporative cooling, ventilation cooling and humidification support
Material DirectionVirgin pulp paper / high-density cellulose cooling media
StructureHoneycomb corrugated wet pad media
Thickness Options10 cm / 15 cm / 20 cm
Size CustomizationHeight and width can be customized according to project requirement
Frame OptionsGalvanized sheet frame, aluminum alloy frame, stainless steel frame
Water Pipe OptionPVC water pipe and project-based water distribution structure
Water Inlet / Outlet OptionsSide inlet-bottom outlet, side inlet-side outlet, top inlet-side outlet, top inlet-bottom outlet
Density Options7090 standard type, 6090 medium density type, 5090 higher density type
Color OptionsBrown, green, black, brown-green mixed, surface green, surface black
System PairingNegative pressure fan, exhaust fan and water circulation system
Application ScenariosLivestock farms, cattle barns, pig houses, poultry houses, greenhouses, workshops and agricultural buildings
CustomizationHeight, width, thickness, frame material, density type, color, water inlet/outlet method and packaging

Water Inlet and Outlet Options

OptionDirectionSuitable Use
ASide inlet + bottom outletCommon side water supply and bottom discharge layout
BSide inlet + side outletSide-to-side water flow layout
CTop inlet + side outletTop water supply with side discharge
DTop inlet + bottom outletTop water distribution and bottom discharge layout

Density and Pad Type Reference

Pad TypeReference CharacterUse Direction
7090 TypeStandard typeCommon evaporative cooling pad use
6090 TypeMedium densityBalanced density and airflow option
5090 TypeHigher densityHigher density pad option for specific project requirements

Frame Material Reference

Frame MaterialMain AdvantageBuyer Notes
Galvanized Sheet FramePractical and commonly used farm frame optionConfirm corrosion and humidity conditions
Aluminum Alloy FrameLighter frame with cleaner appearanceSuitable where appearance and weight matter
Stainless Steel FrameBetter corrosion resistanceSuitable for humid or higher-standard projects

Note: Final cooling pad size, actual wall opening, fan airflow, water circulation design, frame selection and installation layout should be confirmed according to the project drawing.


Applications

  • Cattle Barn Cooling: Helps reduce incoming air temperature in cattle barns when paired with exhaust fans.
  • Pig House Cooling: Suitable for pig houses where summer cooling and air exchange are required.
  • Poultry House Cooling: Can be used in poultry houses with negative pressure fan ventilation systems.
  • Greenhouse Cooling: Supports evaporative cooling and air intake for greenhouse projects.
  • Livestock Farm Ventilation: Works as part of fan-and-pad ventilation systems for farm buildings.
  • Agricultural Workshops: Suitable for workshops and production buildings that need cooling and air exchange.
  • High-Temperature Farm Areas: Useful for hot seasons where barns need more stable temperature management.
  • Custom Cooling Wall Projects: Can be customized by height, width, thickness and frame type according to building openings.
  • Fan-and-Pad Cooling Systems: Works together with fans to form a more complete livestock cooling solution.
  • Barn Renovation Projects: Suitable for farms upgrading from simple ventilation to evaporative cooling systems.

Customization Options

Custom OptionAvailable ChoicesBuyer Notes
Height and WidthCustomized according to building openingProvide opening size and installation drawing
Thickness10 cm, 15 cm, 20 cmSelect by cooling demand and frame design
Frame MaterialGalvanized sheet, aluminum alloy, stainless steelChoose by humidity, corrosion and budget
Density Type7090, 6090, 5090Match airflow, fan pressure and cooling requirement
Water Inlet DirectionSide inlet or top inletConfirm pipe direction before production
Water Outlet DirectionBottom outlet or side outletConfirm drainage and water circulation layout
Water Pipe StructurePVC pipe and customized water distributionConfirm water supply and circulation system
ColorBrown, green, black, mixed or surface color optionsConfirm available production batch
PackagingStandard export packaging or project packagingConfirm shipping method and loading quantity
Bulk Order SupportFarm projects, greenhouse projects and distributorsConfirm quantity and mixed specifications

Why Choose Our Product

  • Clear Barn Cooling Positioning: This page focuses on livestock evaporative cooling pads, not electronic cooling pads or personal cooling mats.
  • Fan-and-Pad System Compatibility: The pad is designed to work with negative pressure fans or exhaust fans for stronger cooling performance.
  • Custom Project Fit: Height, width, thickness, density, frame material and water inlet/outlet method can be configured according to the building opening.
  • Multiple Thickness Options: 10 cm, 15 cm and 20 cm thickness options help match different farm cooling demands.
  • Multiple Frame Choices: Galvanized sheet, aluminum alloy and stainless steel frames can be selected by project environment.
  • Flexible Water Flow Design: Four inlet/outlet combinations support different installation and circulation layouts.
  • Livestock and Agricultural Use: Suitable for cattle barns, pig houses, poultry houses, greenhouses and farm workshops.
  • Practical Export Support: Product photos, specification confirmation, frame selection, packaging advice and loading discussion can be provided before shipment.

Frequently Asked Questions

A livestock cooling pad is used in evaporative barn cooling systems to cool incoming air before it enters livestock houses, greenhouses or agricultural buildings.

Yes. The cooling effect is better when the pad works with negative pressure fans or exhaust fans that pull air through the wet pad wall.

Reference thickness options include 10 cm, 15 cm and 20 cm. The final thickness should be selected according to cooling demand and installation layout.

Yes. Height and width can be customized according to the building opening, barn layout and ventilation system design.

Frame options include galvanized sheet, aluminum alloy and stainless steel. The best option depends on humidity, corrosion conditions and project requirements.

Available methods include side inlet-bottom outlet, side inlet-side outlet, top inlet-side outlet and top inlet-bottom outlet.

Reference options include 7090 standard type, 6090 medium density type and 5090 higher density type. The final choice should match airflow and cooling requirements.

Please provide building type, opening size, required height and width, thickness, frame material, density type, water inlet/outlet direction, fan layout, quantity and destination market.


Related Livestock Equipment

  • For airflow and exhaust ventilation: Livestock barn fans help move air through barns and can work with cooling pads in fan-and-pad cooling systems. View Livestock Fans →
  • For sidewall ventilation control: Barn curtains help manage airflow, wind protection and seasonal ventilation in livestock buildings. View Barn Curtains →
  • For barn comfort flooring: Cow mats and livestock rubber mats help improve floor comfort, traction and cleaning support in livestock areas. View Cow Mats →
  • For livestock housing layout: Cow cubicles and freestall loops help organize dairy cow resting areas and barn comfort zones. View Cow Cubicles →
  • Back to current category: Back to Barn Cooling Systems →

About Us

  • Experience: 10 years of livestock equipment manufacturing since 2016, with a 5,000m² production facility and 8 production lines.
  • Quality Standards: 304 food-grade stainless steel on all water-contact surfaces. 240-hour salt spray testing on galvanized components.
  • Customization: Custom-length fabrication is our standard — tell us your pen dimensions and we build accordingly.
  • Support: CAD layout drawings, assembly manuals, pre-shipment photos and videos for your approval. Remote video guidance and spare parts support included.